
Product Specifications
Performance | |
Modes | CPAP, S, T, ST, VAPS |
Operating / Monitoring Range | CPAP: 4 to 20 cm H₂O; IPAP: 4 to 30 cm H₂O; EPAP: 4 to 28 cm H₂O; VT: 150 to 180 ml |
Ti / Ti Min / Ti Max | 0.2 to 4 sec / 0.2 to 3 sec / 0.4 to 4 sec |
Sensitivity | 1 to 5 levels |
Ramp Time / Rise Time | Off, 5 to 45 mins / 100 to 900 ms |
Peak Flow | 240 LPM |
Respiratory Rate | 4 to 45 BPM |
Gender Selection | Male / Female |
Humidification Level | Off, 1 to 5 level |
Sound Pressure Level | < 28 dBA ± 2 dBA |
Alarms | |
Alarms | Leak Alert with Beep |
Display | |
Display | 2.8-inch LCD |
Physical | |
Dimensions | 28 cm L x 14 cm W x 9.5 cm H (with humidifier) |
Weight | 1.7 kg (with humidifier) |
Tubing Air Outlet | Standard (19 mm) / 22 mm Air Outlet (STD) |
Power | |
Power Adapter | Input Range: 100/240 VAC, 50/60 Hz, 4 A, 90 W (typical consumption) |
Environmental Conditions | |
Operating Conditions | 5° C to 35° C / 10 to 95% RH non-condensing / Sea level to 2,591 m; Air pressure 735 to 1013 hPa |
Storage & Transport Conditions | –20° C to 60° C / 5 to 95% RH non-condensing |
Other Specifications | |
Supplemental Oxygen | Max 4 L/min (CPAP); 15 L/min (S, T, ST, VAPS) |
Data Management | 1/7/31 days, 6 months, 1 year of detailed data |
Standard Air Filter | Pollen Filter (Washable) |
Warranty | 2 years |
This table lists product specifications and features.
FAQs
Where should I place the device for optimal use?
Place the device on a firm, flat surface within easy reach of where you will use it and at a level lower than your sleeping position.
Can I put the system in checked baggage when travelling?
No, the carrying case is designed for carry-on luggage only. It will not protect the system if it is put through checked baggage.
What should I do if I'm travelling with the optional humidifier?
Do not travel with water in the water tank when using the optional humidifier.
How can I make the security process easier when travelling with the system?
There is a note on the bottom of the device stating that it is medical equipment and suitable for airline use. Bringing the manual may also help security personnel understand the Deck Mount Respirare BiPAP VT60 ST device.
What do I need to know about power compatibility when travelling to a different country?
If you're travelling to a country with a different line voltage, you may need a different power cord or an international plug adaptor. Contact your home care provider for more information.