Philips Trilogy Evo O₂ Ventilator delivers reliable support for both noninvasive (NIV) and invasive (IV) ventilation across diverse care environments. Its adaptable design suits hospital and home use, featuring a robust battery and streamlined data access. With intuitive controls and customizable on-demand ventilation, it ensures patient comfort and ease of operation. The Digital Auto-Trak technology automatically synchronises breaths to the patient’s natural patterns, enhancing comfort without manual intervention. Backed by comprehensive clinical support, training resources, and an extended warranty, the Trilogy Evo requires preventive maintenance only every four years, minimising operational costs.
What's in the box
What's in the box
Device
User Manal
Air-Inlet Foam Filter
AC Power Cord with Clamp
Low Pressure O₂ Connector
Passive, Single Limb Circuit
Warranty
Warranty
The manufacturer warrants the unit to be free from defects in materials and workmanship under normal use and operation for a period of two (2) years from the date of purchase. This warranty does not cover the accessories. Any defective part(s) will be repaired or replaced at the manufacturer's option if the unit has not been tampered with or used improperly during that period.
This warranty does not cover damage caused by accident, misuse, abuse, alteration, water ingress, or other defects not related to material or workmanship, and is not extended to the cost of labour incurred in repairing or replacing defective part(s).
To initiate a warranty claim, you can contact us at order-support@respmart.com with "WARRANTY CLAIM" in the subject line. We may reach out to verify the claim before issuing a replacement or return approval.
For approved warranty claims, we’ll take care of the shipping cost to send your replacement or repaired product. We kindly ask that you cover the cost of sending the original product back to us for inspection and verification.
Shipping
Shipping
We at Respmart.com make every effort to ensure you have a smooth and enjoyable shopping experience, including timely order processing and delivery. All orders placed are processed promptly. We make every effort to process and ship your order within 3 business days from the date of purchase. If you have any questions or concerns regarding the status of your order, please contact our support team at order-support@respmart.com
Kindly refer to our Shipping Policy for full details and conditions here.
Return
Return
We at Respmart.com make every effort to ensure that the product you purchase arrives in perfect condition. However, in the unlikely event of a damaged, defective or wrong item delivered, please inform customer service via email on order-support@respmart.com within 48 hours of the delivery along with images of the delivered product.
Kindly refer to our Return and Refund Policy for full details and conditions here.
Operational Care
Operational Care
Cleaning the Device
Clean the outer surface weekly and between patients using a lint-free cloth dampened with a mild detergent solution. Use a soft-bristle brush around buttons and display areas. Wipe with a damp cloth to remove detergent residue, and dry with a clean cloth.
After cleaning, disinfect the exterior weekly using either: keep surfaces wet for 10 minutes, then air dry or use household bleach with 8.25% sodium hypochlorite. Keep surfaces wet for 10 minutes, then air dry. Clean the detachable battery monthly with a cloth and detergent solution. Dry completely before reinstalling. DO NOT immerse in water.
In clinical settings, rinse daily and replace monthly. In home settings, rinse monthly and replace every 6 months. Use only Philips Respironics-approved filters. Never operate the device without the filter. Always unplug the device before cleaning. Never allow liquids to enter the enclosure. Avoid blocking air intakes or exhausts, and ensure proper ventilation clearance (15–30 cm). Use only compatible accessories and do not modify the device.
Share






Want to learn more?
Click below to dive into product specifications, FAQs, manuals, brochures and other similar models — all in one place.

For use in dynamic environments
With expanded cross-functionality, Trilogy Evo offers features to treat chronic and critical patients in a variety of settings, such as sub-acute or chronic care environments, a patient’s home or during their activities. It's designed specifically with durability in mind to protect it against damage during travel, such as during medical transport.

Long-lasting battery life
Ventilator-dependent patients are supported by internal and detachable batteries, now with 15-hour battery life. Compared to Trilogy 100's six-hour battery, Trilogy Evo gives patients a new level of freedom and mobility. It's ready to be mounted onto a roll-stand or a wheelchair, with a mountable, easy-to-use carry bag.

Meet your patients’ changing needs
Trilogy Evo provides noninvasive and invasive ventilator support with added sensitivity for a wide range of adult and pediatric patients. Volume and pressure modes, AVAPS-AE, SpO2, and EtCO2 monitoring and alarms of every parameter allow for adaptable care. Flexibility of circuits allows them to be used in a wide range of patients.

Easy access to data
Trilogy Evo allows you to view patient therapy data through Care Orchestrator, our cloud-based patient management System. Therapy data is downloaded at the point of care through a USB drive.

Intuitive navigation
Trilogy Evo is designed for easy navigation and fast set-up of prescriptions. New features can simplify day-to-day use for caregivers and patients, including an 8” touchscreen that uses patient-friendly displays to support easy set-up and setting modification. It offers new, on-screen Help and Alarm guidance and user-friendly universal names for most ventilation modes.

Reliability from a trusted source
The newest Trilogy device was made to be user-friendly without compromising the advanced features of the innovative Trilogy family technology. SpO2, EtCO2 and advanced respiratory mechanics monitoring capabilities are designed to help you optimise your patient’s therapy.

Adapting with every breath
Proven innovations are designed to treat the varying needs of respiratory insufficiency. AVAPS automatically adjusts the ventilator support to reach the desired tidal volume, while Auto EPAP proactively adjusts to the lowest effective pressure to manage the upper airway. Auto Back-up Rate delays a machine breath until your patient exhales to maximise comfort.

On-demand ventilation
The mouthpiece ventilation does not require any inspiratory effort to trigger a breath. Our unique kiss® trigger detects when your patient engages or disengages from the mouthpiece to deliver on-demand ventilation, with the security of patient alarms.
Specifications
-
Ventilation modes - A/C-PC, A/C-VC, CPAP, PSV, S/T, SIMV-PC, SIMV-VC, MPV-PC, MPV-VC
Weight - 5.2 kg
Size - 16.5 cm x 28.6 cm W x 24.5 cm H
Screen dimensions - 20.32 cm
Oxygen Low flow - 0 to 30 l/min; maximum 10 psi
Oxygen High pressure - 41 to 87 psi
Tidal volume - 0 to 2000 ml
Leak - 0 to 200 l/min
Peak inspiratory flow - 0 to 200 l/min
Mean airway pressure - 0 to 90 cm H₂O
I:E ratio - 9.9:1 to 1:9.9
Dynamic resistance - 5 to 200 cm H₂O/l/sec
Auto-PEEP - 0 to 20 cm H₂O
SpO₂ with pulse oximeter accessory - 0 to 100 %
EtCO₂ with CO₂ accessory - 0 to 150 mm Hg
Minute ventilation - 0 to 30 l/min
Respiratory rate - 0 to 90 BPM
Peak inspiratory pressure - 0 to 90 cm H₂O
Percentage spontaneous triggered breaths - 0 to 100%
Dynamic compliance - 1 to 100 ml/cm H₂O
FiO₂ with FiO₂ sensor - 21% to 100%
Pulse rate with pulse oximeter accessory - 18 to 321 beats per minute
AC input voltage - 100/240 VAC, 50/60 Hz, 1.7/0.6 A
Internal and detachable Li-ion batteries - 15 hours nominal total run time (7.5 hours each battery)
DC input voltage - 12/24 V 6.5 A
-
Charge time for detachable and internal battery - from 0% to 80%: 2.5 hours; from 0% to 100%: 3.5 hours
Alarms:
Inspiratory Pressure - PEEP+1 to 89 cm H₂O
Minute Ventilation - OFF, 0.2 to 30 L/min
Circiut Disconnection - OFF, 5 to 60 sec
No trigger - OFF; 0.5 to 15 min (Only in MPV)
Tidal Volume - OFF, 10 to 2000 ml
Respiratory Rate - OFF, 1 to 90 BPM
Apnea Interval - 5 to 60 sec
Controls:
AVAPS with passive circuit - PSV, S/T, and A/C-PC modes only
Breath rate - 0 to 80 BPM
EPAP / CPAP - 3 to 25 cm H₂O
Pressure support/pressure control - 0 to 60 cm H₂O
Rise time - 0 to 6
Flow trigger sensitivity - 0.5 to 9 l/min
Flow pattern - Square, Ramp
Inspiratory time min/max - 0.3 to 3.0 sec
Tidal volume - 35 to 2000 ml on Dual Limb & Active Flow circuits, 50 to 2000 ml on passive & active PAP circuits
PEEP - 0 to 35 cm H₂O for active circuits, 3 to 25 cm H₂O for passive circuits
IPAP - 3 to 60 cm H₂O
Inspiratory time - 0.3 to 5.0 sec
Triggering and cycling - Off, AutoTra, Sensitive, AutoTrak, and Flow Trigger
Flow cycle sensitivity - 10% to 90% of peak flow
FiO₂ - 21% to 100%
Backup ventilation - ON - OFF
FAQs
Q: What is the Philips Trilogy Evo used for?
A: The Trilogy Evo is a portable ventilator designed to provide invasive and non-invasive ventilatory support for adult and pediatric patients with respiratory insufficiency or failure.
Q: Is Trilogy Evo battery-operated?
A: Yes, Trilogy Evo comes with an internal battery and supports an optional detachable battery module, providing extended use during travel or power outages.
Q: How long does the battery last?
A: The internal battery provides up to 3 hours of operation. With the external detachable battery, the runtime can be extended to up to 15 hours, depending on usage and settings.
Q: Can I use any bacterial filter with the device?
A: No. Only Philips Respironics-approved bacterial filters that meet ISO 23328-1 and ISO 23328-2 standards should be used to avoid system performance issues.
Q: Does the Trilogy Evo work without the filter?
A: No. Operating the device without the air inlet filter may cause contamination and damage to the ventilator.