Skip to product information
1 of 2

ResMed

AirStart 10 APAP

AirStart 10 APAP

SKU:37365

Regular price Rs. 26,500.00
Regular price Sale price Rs. 26,500.00
Sale Sold out
Taxes included. Shipping calculated at checkout.
Quantity

In stock

The ResMed AirStart™ 10 is a compact device designed for easy setup and use. Available in auto-adjusting (APAP) or fixed-pressure (CPAP) modes, it features an integrated HumidAir humidifier and simple controls for convenience. With a lightweight design and quiet motor, the AirStart 10 focuses on practicality and reliable operation.

What's in the box

Device
HumidAir™ humidifier
User Manual
Air tubing
Standard filter (already installed)
Power supply unit
Travel bag
SD card (already installed)

Warranty

The manufacturer warrants the unit to be free from defects in materials and workmanship under normal use and operation for a period of two (2) years from the date of purchase. This warranty does not cover the accessories. Any defective part(s) will be repaired or replaced at the manufacturer's option if the unit has not been tampered with or used improperly during that period.
This warranty does not cover damage caused by accident, misuse, abuse, alteration, water ingress, or other defects not related to material or workmanship, and is not extended to the cost of labour incurred in repairing or replacing defective part(s).
To initiate a warranty claim, you can contact us at order-support@respmart.com with "WARRANTY CLAIM" in the subject line. We may reach out to verify the claim before issuing a replacement or return approval.
For approved warranty claims, we’ll take care of the shipping cost to send your replacement or repaired product. We kindly ask that you cover the cost of sending the original product back to us for inspection and verification.

Shipping Policy

We at Respmart make every effort to ensure you have a smooth and enjoyable shopping experience, including timely order processing and delivery. All orders placed are processed promptly. We make every effort to process and ship your order within 3 business days from the date of purchase. If you have any questions or concerns regarding the status of your order, please contact our support team at order-support@respmart.com
Kindly refer to our Shipping Policy for full details and conditions here.

Return Policy

We at Respmart make every effort to ensure that the product you purchase arrives in perfect condition. However, in the unlikely event of a damaged, defective or wrong item delivered, please inform customer service via email on order-support@respmart.com within 48 hours of the delivery along with images of the delivered product.
Kindly refer to our Return and Refund Policy for full details and conditions here.

Operational Care

Place the device on a stable and horizontal surface when operating. Make sure the air vent openings are not obstructed; never place the unit on a soft surface, such as a bed or couch, where the air opening may be blocked
Only use compatible parts and seek an authorised service centre for maintenance needs. Never open the device; there are no serviceable parts within the unit.
Cleaning the Device
To avoid electrical shock, turn off and disconnect the device before cleaning it with a damp cloth and mild household cleaner. DO NOT immerse the device in any fluids.
Rinse the reusable pollen filter every two weeks and replace it every six (6) months.
Wash the humidifier and air tubing in warm water using mild detergent. DO NOT wash in a dishwasher or washing machine.
Rinse the humidifier and air tubing thoroughly and allow to dry out of direct sunlight and/or heat.
Wipe the exterior of the device with a dry cloth.
⚠ Cautions
DO NOT install a wet filter into the device. You must ensure sufficient drying time for the filter.
View full details

Product Specifications

Product specifications for AirStart 10 APAP
Power
AC Input Range 100/240 VAC, 50/60 Hz, 1.0/1.5 A, Class 2 115 V, 400 Hz, 1.5 A (nominal for aircraft use)
DC Output 24 VDC, 3.75 A
Typical Power Consumption 53 W (57 VA)
Peak Power Consumption 104 W (108 VA)
Environmental Conditions
Operating Temperature 5° C to 35° C
Operating Humidity 10 to 95% RH (non-condensing)
Operating Altitude Sea level to 2,591 m; Air pressure 1013 hPa to 738 hPa
Storage & Transport Temperature -20° C to 60° C
Storage & Transport Humidity 5 to 95% RH (non-condensing)
Physical
Ingress Protection IP22
Dimensions 11.6 cm H × 25.5 cm W × 15 cm
Air Outlet 22 mm
Weight 1.34 kg
Water Capacity Max 380 ml
Performance
Sound Pressure Level Max 35 dBA ± 2 dBA
Operating Modes & Pressure Range APAP, CPAP: 4 to 20 cm H₂O
Supplemental Oxygen Max 4 L/min

This table lists product specifications and features.

FAQs

Where should I place the device for use?

Place the device on a firm, flat surface within easy reach, and ideally at a level slightly lower than your sleeping position.

Can I put the system in checked baggage when travelling?

No. The carrying case is designed for carry-on luggage and may not protect the system in checked baggage.

What should I do if I’m travelling with the humidifier?

Always empty the water tank before travelling. Do not transport the device with water inside.

How can I make the security process easier when travelling with the system?

The device is safe to be transported and used in flight. There is a note on the bottom of the device stating that it is medical equipment and suitable for airline use. Bringing the manual may also help security personnel understand the Stellar 100 V device. Click ResMed AirStart 10 flight travel compliance letter (PDF) to download the manufacturer's flight safety declaration.

What about power compatibility when travelling internationally?

The AirStart 10 supports a wide voltage range, but you may need a different power cord or plug adaptor depending on the country.

Need help? Submit your questions below.

Didn’t find what you were looking for? Send us your question below, and our team will be happy to assist you with product details or support.

Your Questions